Create an account and/or login for access.

Redirecting back to table of contents...
CS R302.2.3 Guest User

Not Completed

Value: 43
TEST SITE -*- TEST SITE -*- TEST SITE ™ Table of Contents Listen 

R302.2.3


Section R302.2.3 is titled 'Continuity' and covers requirements for townhouse fire-resistance rated construction. The requirement for a fire-resistance-rated assembly separating townhouses to be continuous from foundation to the roof sheathing or deck, and for the rating to extend the full length of the assembly, including between attached enclosed accessory structures is established. The purpose of this section is to slow the spread of fire, heat, and smoke between adjacent units.

The model shows an x-ray of the skin of a three-unit townhouse with the separating assemblies being continuous from the foundation to the underside of the roof assembly.